PROFIBUS Configuration 3-3

Status Register

The Status Register reflects the overall status of the module as follows:

Table 3.2 Status Register contents

• Bit 0

Trip – Same functionality as bit 0 in parameter 5, Device Status.

• Bit 1

Warning – Same functionality as bit 1 in parameter 5, Device Status.

• Bit 2

OutA Stat – Same functionality as bit 2 in parameter 5, Device Status.

• Bit 4

Input 1 – Same functionality as bit 3 in parameter 5, Device Status.

• Bit 5

Input 2 – Same functionality as bit 4 in parameter 5, Device Status.

• Bit 6

Save Ready – Used to indicate that a save of parameter values of parameters mapped as
Cyclic I/O has been performed. The bit can be cleared again by clearing the "Save"-bit
in the Control Register.

• Bit 7

Motor Current – Same functionality as bit 5 in parameter 5, Device Status.

Parameter Programming

Program Lock

Parameter 20, Program Lock, provides a degree of security from having parameter settings
unintentionally altered when programmed to the “locked” setting.
If enabled, all parameters except Program Lock (20) are protected from acyclic (DP-V1) write
access, and any changes made to the value of parameters mapped as Cyclic I/O will be ignored.
The "Program Lock" parameter will, if mapped as Cyclic I/O, be processed prior to processing
other parameters mapped as Cyclic I/O. The loading of initial data is not affected by the
Program Lock.

Bit

Function:

7

6

5

4

3

2

1

0

X

Trip

X

Warning

X

OutA Stat

X

Not Used

X

Input 1

X

Input 2

X

Save Ready

X

Motor Curr.