I/o mapping – Rockwell Automation 150 USE MN/SMC DIALOG + CONTROLLER User Manual

Page 134

Advertising
background image

Serial Communications

8-25

Example Information

The SMC Dialog Plus controller does not support Datalinks.

Switch Settings

I/O Mapping

The SMC Dialog Plus controller’s first two words of data are pre-
configured in the 1203-GK5 communication module as follows:

The SMC Dialog Plus controller does not utilize this feature; a value of zero should be given.

The feedback word is the value of parameter 4, Current Phase A.

Description

Switch Setting

Node Address:

13

SW2, Switches 1, 3 & 4 (On)
Switches 2, 5 & 6 (Off)

Data Rate:

125k

SW2, Switches 7 & 8 (Off)

Datalinks:

No

SW1, Switches 1 - 4 (Off)

Zero data to logic command on
fault:

Yes

SW1, Switch 6 (Off)

Fault on comm loss:

Yes

SW1, Switch 7 (Off)

Fault on PLC/SLC program/idle
modes:

Yes

SW1, Switch 8 (Off)

Disabled Datalink A (Off)
Disabled Datalink B (Off)
Disabled Datalink C (Off)
Disabled Datalink D (Off)
Not Used (Off)
Zero Data (Off)
Fault on Comm Loss (Off)
Fault on Program/Idle (Off)

SW

1

SW

2

8

8

7

7

6

6

5

5

4

4

3

3

2

2

1

1

Node Address 13 (On)
Node Address 13 (Off)
Node Address 13 (On)
Node Address 13 (On)
Node Address 13 (Off)
Node Address 13 (Off)
Data Rate = 125k (Off)
Data Rate = 125k (Off)

Word

Output Data

Input Data

1

Logic Command

Logic Status

2

Reference

Feedback