Troubleshooting

Table 10.B Motor Will Not Start — No Output Voltage to the Motor

Table 10.C Motor Rotates (but does not accelerate to full speed)

Table 10.D Motor Stops While Running

Display

Possible Cause

Possible Solutions

Fault displayed

•

See fault description

•

See Table 10.A
addressing fault
conditions

Display is blank

•

Control voltage is
absent

•

Failed control module

•

Check control wiring and
correct if necessary

•

Replace control module

Stopped

0.0 Amps

•

Pilot devices

•

SMC Enable input is
open at terminal 13

•

Terminal 15 is open on
Soft Stop, Pump
Control, and SMB

•

Start-Stop control has
not been enabled for
the human interface
module

•

Control voltage

•

Failed control module

•

Check wiring

•

Check wiring

•

Check wiring

•

Follow the instructions on
pages 2-13 and 2-14 to
enable control capability

•

Check control voltage

•

Replace control module

Starting

•

Two or three power
phases are missing

•

Check power system

Display

Possible Cause

Possible Solutions

Fault displayed

•

See fault description

•

See Table 10.A
addressing fault
conditions

Starting

•

Mechanical problems

•

Inadequate Current
Limit setting

•

Failed control module

•

Check for binding or
external loading and
correct

•

Check motor

•

Adjust the Current Limit
Level to a higher setting

•

Replace control module

Display

Possible Cause

Possible Solutions

Fault displayed

•

See fault description

•

See Table 10.A
addressing fault
conditions

Display is blank

•

Control voltage is
absent

•

Failed control module

•

Check control wiring and
correct if necessary

•

Replace control module

Stopped

0.0 Amps

•

Pilot devices

•

Failed control module

•

Check control wiring and
correct if necessary

•

Replace control module

Starting

•

Two or three power
phases are missing

•

Failed control module

•

Check power system

•

Replace control module