Using the trend features, Chapter – Rockwell Automation 1336T ControlNet Frn1.02 Rev 1.5 User Manual
Page 203
Chapter
8
Publication 1336 FORCE–5.18 ––March, 1999
Using the Trend Features
Trending is a diagnostic tool that you can use to capture and retain an
input parameter data value until a trigger condition occurs. The
FORCE has the capacity to setup and monitor up to 4 parameters,
Trend 1 through Trend 4. With trending, you program the:
•
Parameter to sample
•
Trigger condition
•
Sampling rate
•
Quantity of samples to be taken after the trigger occurs
•
Whether trending is to occur one time or continuously
Parameters used by trending are shown in the table below:
Description
Trend 1
Parameter
Number:
Trend 2
Parameter
Number
Trend 3
Parameter
Number
Trend 4
Parameter
Number
Source
454
464
474
484
Variable X Source
455
465
475
485
Variable Y Source
456
466
476
486
Operator (comparison type)
457
467
477
487
Sampling Rate
458
468
478
488
Quantity of Post-Trigger Samples
459
469
479
489
Mode
460
470
480
490
Select
461
471
481
491
Status
462
472
482
492
Output
463
473
483
493
Identify the number of the parameter you want to sample as follows:
If you are programming
Trend #:
Then enter the number of the parameter to be
sampled in:
1
454
2
464
3
474
4
484
Setting Up Trending
Selecting the Parameter to
Sample