8–3
Using the Trend Features
Publication 1336 FORCE–5.18 ––March, 1999
5. Select the number that corresponds to the desired operator using
the table below:
Number
This
Operator
Compare:
0
GT (Greater Than)
Data Values for X and Y
1
LT (Less Than)
Data Values for X and Y
2
EQ (Equal)
Data Values for X and Y
3
NE (Not Equal)
Data Values for X and Y
4
AND
16–bit word in X to a 16 bit mask in Y
5
NAND (Negated AND)
16–bit word in X to a 16 bit mask in Y
6
OR
16–bit word in X to a 16 bit mask in Y
7
NOR (Negated OR)
16–bit word in X to a 16 bit mask in Y
Important: Remember that the trigger condition is compared in the
following manner [Variable X] [Operator] [Variable Y].
6.
If you are programming
Trend:
Then enter the operator in:
1
Parameter 457
2
Parameter 467
3
Parameter 476
4
Parameter 486
"