Rockwell Automation 1305 AC Drive, Series C, Firmware 6.xx and Up User Manual
Page 113

Programming
5-45
Diagnostics Group
(continued)
[Freq Source]
Parameter # 62
[Freq Source]
Parameter Type Read
This parameter displays the frequency source currently
commanding the drive.
Units Text
Displays ‘‘Remote Pot”
‘‘0-10 Volt”
‘‘4–20 mA”
‘‘MOP”
‘‘Adapter 1”
‘‘Adapter 2”
‘‘Adapter 3”
‘‘Adapter 4”
‘‘Adapter 5”
‘‘Adapter 6”
‘‘Preset 1”
‘‘Preset 2”
‘‘Preset 3”
‘‘Preset 4”
‘‘Preset 5’’
‘‘Preset 6”
‘‘Preset 7”
[Freq Command]
Parameter # 65
Factory Default 0.00 Hz
[Freq Command]
Parameter Type Read Only
Minimum 0.00 Hz
This parameter displays the frequency that the drive is
commanded to output. This command may come from any
one of the frequency sources selected by [Freq Select 1],
[Freq Select 2] or [Preset Freq 1-7] as determined by
inputs to SW1, SW2 and SW3 at TB2.
Units 0.01 Hz
Maximum 400.00 Hz
[Drive Direction]
Parameter # 69
Factory Default ‘‘Forward’’
[Drive Direction]
Parameter Type Read Only
This parameter displays the running direction of the drive.
Units Text
Displays ‘‘Forward”
‘‘Reverse”
[Motor Mode]
Parameter # 43
[Motor Mode]
Parameter Type Read Only
This parameter is used for internal diagnostic purposes.