Nvs functions, Plc block transfer emulation instruction data, Message operation – Rockwell Automation 1203-EN1 EtherNet/IP-to-SCANport Module User Manual
Page 160: F-16

F-16
Supported Emulated Block Transfer Commands
NVS (Non-Volatile Storage) Functions activates the specified NVS
functions.
PLC Block Transfer Emulation Instruction Data
PLC request instruction length: 4 words
Drive response instruction length: 3 words
Figure F.8 NVS Functions Message Structure
Message Operation
The NVS storage function allows three different message requests:
• NVS Save saves parameter information from the working memory or
RAM to NVS Storage.
• NVS Recall retrieves the last saved data from NVS Storage and places
it in the working memory or RAM.
• NVS Default Initialize clears the RAM and NVS Storage and sets all
parameter values to default.
If an error has occurred, response word 1 returns a value of -31998.
NVS Functions
Header
Word 0
PLC Decimal Value
–31998
Header
Word 1
Header
Word 2
PLC Request
Header Word 0
Header Word 1
Header Word 2
Message Length
Message Length
PLC Decimal Value
770 — Message OK
–31998 — Message Error
0
Drive Response
4
0
Data Word 3
NVS Command
Value
NVS Command
00
01
02
03
Not Used
NVS Save
NVS Recall
NVS Default Initialize
3