Message operation, Example, Data file format – Rockwell Automation 1203-EN1 EtherNet/IP-to-SCANport Module User Manual
Page 165

Supported Emulated Block Transfer Commands
F-21
Figure F.11 Fault Queue Size Message Structure
Message Operation
Fault Queue Size reads back the size of the fault queue available in the
product. Each product may have a different number of fault queue entries
available for storage.
If an error has occurred, word 1 of the response returns a value of
-30975.
Example
In this example, a 1336 PLUS drive was used. This product has a fault
queue of four storage locations available to store faults. This value is
seen in word 3 of the response header message.
Data File Format
* Example only — These values vary depending on parameters and products.
Header
Word 0
PLC Decimal Value
1793
Header
Word 1
Header
Word 2
PLC Request
Header Word 0
Header Word 1
Header Word 2
Message Length
Message Length
PLC Decimal Value
1793 — Message OK
–30975 — Message Error
0
Drive Response
3
0
4
Fault Queue Size
Data
Word 3
0
1
2
3
4
5
6
7
8
9
PLC request
3
1793
0
Drive response
4
1793
0
4*