The following information applies when operating this
equipment in hazardous locations:
Informations sur l’utilisation de cet équipement en
environnements dangereux :
Products marked “CL I, DIV 2, GP A, B, C, D” are suitable
for use in Class I Division 2 Groups A, B, C, D, Hazardous
Locations and nonhazardous locations only. Each product is
supplied with markings on the rating nameplate indicating
the hazardous location temperature code. When combining
products within a system, the most adverse temperature code
(lowest “T” number) may be used to help determine the
overall temperature code of the system. Combinations of
equipment in your system are subject to investigation by the
local Authority Having Jurisdiction at the time of
installation.
Les produits marqués "CL I, DIV 2, GP A, B, C, D" ne
conviennent qu’à une utilisation en environnements de
Classe I Division 2 Groupes A, B, C, D dangereux et non
dangereux. Chaque produit est livré avec des marquages sur
sa plaque d’identification qui indiquent le code de
température pour les environnements dangereux. Lorsque
plusieurs produits sont combinés dans un système, le code de
température le plus défavorable (code de température le plus
faible) peut être utilisé pour déterminer le code de
température global du système. Les combinaisons
d’équipements dans le système sont sujettes à inspection par
les autorités locales qualifiées au moment de l’installation.
EXPLOSION HAZARD
•
Do not disconnect equipment 
unless power has been 
removed or the area is known 
to be nonhazardous. 
•
Do not disconnect connec-
tions to this equipment unless 
power has been removed or 
the area is known to be non-
hazardous. Secure any external 
connections that mate to this 
equipment by using screws, 
sliding latches, threaded con-
nectors, or other means pro-
vided with this product.
•
Substitution of components 
may impair suitability for 
Class I, Division 2.
•
If this product contains batter-
ies, they must only be changed 
in an area known to be non-
hazardous.
RISQUE D’EXPLOSION
•
Couper le courant ou s’assurer 
que l’environnement est classé 
non dangereux avant de 
débrancher l'équipement.
•
Couper le courant ou s'assurer 
que l’environnement est classé 
non dangereux avant de 
débrancher les connecteurs. 
Fixer tous les connecteurs 
externes reliés à cet équipe-
ment à l'aide de vis, loquets 
coulissants, connecteurs filetés 
ou autres moyens fournis avec 
ce produit.
•
La substitution de composants 
peut rendre cet équipement 
inadapté à une utilisation en 
environnement de Classe I, 
Division 2.
•
S’assurer que l’environne-
ment est classé non dangereux 
avant de changer les piles.
WARNING
!