Import user page files to the controller – Rockwell Automation 1785-ENET PLC-5 Ethernet Interface Module Installation Instructions User Manual

Page 38

Advertising
background image

38 PLC-5 Ethernet Interface Module

Publication 1785-IN019B-EN-P - January 2007

All other file types are displayed in an appropriate format. If a % format modifier is
present, the format may be changed by clicking on the file type/number via a Web
browser.

#expand - legal values are #c and #e. This modifier determines whether the

structure file types are displayed in their expanded or compacted formats. If a #
modifier is present, the format may be changed by clicking on the [+]/[-] via a Web
browser. If a #modifier is not present, the default display of expanded will not be
used.

!comment - data after the exclamation point and up to the closing > will be displayed

in the Comment column of the monitor.

Fixed display formats - float files are always output in floating-point format

(“C”%g format). String files are always output as a null-terminated text string. Binary
files are always output as two binary bytes. ASCII files are displayed in a memory
dump format.

Import User Page Files to the Controller

Use RSLogix5 software to import user page files to the controller’s ASCII files:

1. Right-click the ASCII file where you will import the user page file in the Project

folder (under the Data Files folder).

2. Click Properties.

3. Click Import HTML.

4. Use the browser to locate the user page file you want to import.

5. Double-click the file to select it.

6. Click OK.

7. Repeat this process for each user page file.

8. Go online with your controller when all user page files have been imported.

9. Select the User Provided Pages link to view the User Provided Pages menu.

10. Click User Provided Page # to display that specific page.

11. Click the link under the file heading to display an ASCII dump of the ASCII file.

12. Select User Provided Page #4.