8 PLC-5 Ethernet Interface Module
Publication 1785-IN019B-EN-P - January 2007
When you create a hostname, consider these naming conventions.
• The hostname can be a text string up to 24 characters.
• The hostname can contain alphanumeric (A through Z, 0...9) and may contain a 
period and minus sign.
• The first character must be an alpha character.
• The last character must not be a minus sign.
• You cannot use blank spaces or space characters.
• The hostname is not case-sensitive.
Auto Negotiate Speed and Duplex Selection
In the Edit Channel 3A properties dialog, you can either leave the Auto Negotiate checkbox 
checked, which lets the controller negotiate a speed and duplex port setting, or you can 
uncheck the Auto Negotiate checkbox, which forces the port setting to a particular speed and 
duplex port setting.
If you uncheck the Auto Negotiate checkbox, the port setting lets you select the range of 
speed and duplex settings that the controller negotiates. The default port setting with Auto 
Negotiate checked is 10/100 Mbps half duplex, which lets the controller negotiate any of its 
four available settings.
The following table lists the order the controller negotiates for each setting.
Set Negotiation Order
Setting
100 Mbps 
Full Duplex
100 Mbps 
Half Duplex
10 Mbps 
Full Duplex
10 Mbps 
Half Duplex
10/100 Mbps Full 
Duplex/Half Duplex
1st
2nd
3rd
4th
100 Mbps Full Duplex or 
100 Mbps Half Duplex
1st
2nd
3rd
100 Mbps Full Duplex or 
10 Mbps Full Duplex
1st
2nd
3rd
100 Mbps Half Duplex or 
10 Mbps Full Duplex
1st
2nd
3rd
100 Mbps Full Duplex
1st
2nd
100 Mbps Half Duplex
1st
2nd
10 Mbps Full Duplex
1st
2nd
10 Mbps Half Duplex Only
1st