Addressing from data highway plus chapter 5 – Rockwell Automation 1779-KP5_KP5R ORD.1779-5.3 User Manual

Page 47

Advertising
background image

Addressing from Data Highway Plus

Chapter 5

5Ć5

Data Highway Plus to a SynchronousĆDevice Interface (1779ĆKFM, ĆKFMR)

The following example shows a PLC-5 message instruction (displayed by
the T50) that writes 100 words of data from the PLC-5, starting at
Memory Location N100:0. The command is a PLC-2-type command and
stores the data at Memory Offset 010 in the computer.

MESSAGE INSTRUCTION DATA ENTRY FOR CONTROL BLOCK N13:0

Read/Write:

WRITE

PLC-5 Data Table Address:

Press a key to change a parameter or <RETURN> to accept parameters.
[

Program

No Forces

No Edits

PLC-5/15 ADDR 20

READ/
WRITE

F1

PLC-5
ADDRESS

F2

SIZE IN
ELEMENTS

F3

LOCAL/
REMOTE

F4

REMOTE
STATION

F5

LINK
ID

F6

Remote Station:
Link ID:
Remote Link Type:

Size in Elements:
Local/Remote:

Local Node Address:
Processor Type:
Destination Data Table Address:

N100:0
100
REMOTE
Node = 012 User = 001
00
DATA HIGHWAY II
50
PLC-2
010

REMOTE
LINK

F7

LOCAL
NODE

F8

PROC.
TYPE

F9

DESTIN
ADDR

F10

BLOCK SIZE = 10 WORDS