Using 6200 Series Software
Version 2.1 and Earlier
Appendix B
BĆ3
When you use 6200 Series software Version 2.1 (or earlier) to
communicate from a node on Data Highway Plus to a:
computer/1779-KFL on Data Highway II
node on a remote Data Highway Plus network
you must manually enter the USER number into the message control file.
After you have entered a message instruction, enter the USER number
byte into the message control file using the following procedure:
1.
Make sure the cursor is not on an instruction, then press [F8] - Data
Monitor.
2.
Enter the control block address (for example, N13:0) and press the
ENTER key. The following type of display will appear:
Address
N13:0
0000 2728 0064 0407 0064 0000 000B 0002 1000 0400
N13:10
0000
0
1
2
3
4
5
6
7
8
9
Press a key or enter value.
N13:0 = [
Program
No Forces
Hex/BCD Data
Decimal ADDR
PLC-5 ADDR 13
CHANGE
RADIX
F1
SPECIFY
ADDRESS
F5
NEXT
FILE
F7
PREV
FILE
F8
NEXT
PAGE
F9
PREV
PAGE
F10
The control file is displayed in words, not bytes.
The default radix for the display is in decimal. When you want to
change only the single byte for the user number, it is easier to select
hex/BCD as the radix of the display.
Entering the User Number into