Using 6200 Series Software

Version 2.1 and Earlier

Appendix B

BĆ4

3.

Determine the location of the USER number byte based on the
following information.

The message control file is a variable length file with the following
layout:

Type of Data

Number of

Bytes

Status Value

Error Value

Link Type

Local Destination Address (1779ĆKP5 Address)

Number of Bytes in Source Address

Source Address

Link ID

Remote Destination Address

USER Number

Number of Bytes in Destination Address

Destination Address

1784ĆT50 Information

1

1

1

1

1

Variable

2

1

1

1

Variable

2

The USER number always follows the Remote DST address in this
file.

4.

Use the right cursor [ >] key to move to the word containing the
USER number byte. Enter the USER number (in hex) on the display
line, as well as the value for the other byte in the word, and press the
[ENTER] key. This changes the value in the specified word to
include the USER number.

Important: When you enter the value for the word containing the USER
byte, do not change the value of the other byte in the word.

The following screens show the control file during the change and after
the change: