Assigning FT Activation Licenses to Support the 
FTMS Point Source (FactoryTalk Historian SE)
Before adding trusts to FactoryTalk Historian SE, you must assign 
activation licenses to support the FTMS point source in order to 
successfully transfer data between FactoryTalk Historian ME and 
FactoryTalk Historian SE. Activation licenses are assigned for 
FactoryTalk Historian SE in the FactoryTalk Administration 
Console (on the Client Tools CD shipped with your FactoryTalk 
Historian ME module).
Application Trusts (FactoryTalk Historian SE)
To successfully transfer data between FactoryTalk Historian ME 
and FactoryTalk Historian SE, you must create two application 
trusts on the FactoryTalk Historian SE server: webs and 
datatransfer. To do so, perform the following steps:
1.
Launch the FactoryTalk Historian SE SMT application. From 
the Windows Start menu run Programs > Rockwell Software > 
FactoryTalk Historian SE > System Management Tools.
2.
After SMT launches, go to the left-side System Management 
pane and click [+] next to the [Security] item.
3.
From the list of Security plug-ins, click the Trusts option.
4.
From the Trust menu bar in the main window, select the drop-
down menu on the [New] option. The Wizard option is 
checked by default.
5.
The Add Trust Wizard window is launched. The Trust Wizard 
will ask for various pieces of information to create a trust on