3-6 SynchLink Module Features
transferred between them). The SynchLink module can receive and 
transmit data and, therefore, uses a Receive Port Communications 
Format and Transmit Port Communications Format.
SynchLink messages are structured as six 32-bit words; the words are 
divided into three types as described in Table 3.3:
The Communications Formats available on the 1756-SYNCH module 
use various combinations of the words described in Table 3.3. The following 
choices are available:
• 1 Axis, 3 Direct Words, 14 Buffered
• 2 Axis
• 2 Axis, 3 Direct Words
• 2 Direct Words, 18 Buffered
• 4 Direct Words, 18 Buffered
• 4 Direct Words, 8 Buffered
• No Receive Data - Available on the Receive Port only
• Listen Only, No Transmit Data - Available on the Transmit 
Port only
• No Transmit Data - Available on the Transmit Port only
Table 3.3
Word Type:
Description:
Direct
Data delivered in a single message. A SynchLink message can contain 
a maximum of four direct data words; each word is 32 bits in length. 
Direct data can be automatically forwarded to the next node in the 
daisy chain and ring configurations.
Buffered
Data that exceeds the four word limit of a direct data transfer. 
Buffered data is appropriately segmented at the transmitting module 
and reassembled at the receiving module. Buffered data cannot be 
automatically forwarded to the next node in the daisy chain and ring 
configurations.
Axis data
Motion data used by the motion planner in the controller. The 
1756-SYNCH module can consume an Axis tag from a controller and 
pass it over SynchLink. A controller in another chassis can then 
consume axis tags passed over SynchLink from the 1756-SYNCH 
module in that chassis. This data is not automatically forwarded in 
daisy chain or ring configurations.