Rockwell Automation 1756-SYNCH ControlLogix SynchLink Module User Manual User Manual
Page 47
 
Publication 1756-UM521C-EN-P - July 2004
SynchLink Module Features 3-19
For more information on configuring your SynchLink modules, see Chapter 5.
Dependence on SynchLink is Not Required
• The module is a Time Slave on SynchLink.
• The module is the CST Time Master of the local chassis.
• You MUST have selected another module on the fiber optic 
cable to be the SynchLink CST Master.
• If your 1756-SYNCH module uses firmware revision 2.18
or greater and communications with the SynchLink CST 
Master are not present at power-up, the module 
automatically becomes the Time Master of its local chassis. 
If a Time Slave 1756-SYNCH module becomes the Chassis 
CST Master without the SynchLink CST master, then the 
slave chassis is running unsynchronized motion. 
Unsynchronized motion may be acceptable when 
troubleshooting or performing machine maintenance. When 
synchronized motion is required the application logic in the 
slave chassis must check the proper status bit in the slave 
1756-SYNCH module.
• If your 1756-SYNCH module uses firmware revision 2.10
or earlier and communications with the SynchLink CST 
Master are not present at power-up, CST-dependent 
features will not start operating until the communications to 
the SynchLink CST Master are restored.
• If communications with the SynchLink CST Master are
broken after operation has begun, the module continues to 
relay time and acts as Chassis CST Master. In this case, the 
chassis is running unsynchronized motion that you must 
account for in your application’s logic.
IMPORTANT: If your 1756-SYNCH is running unsynchronized 
motion (i.e. because the connection to a SynchLink CST Master 
either broke or never existed), when communications are resumed 
with the Master over the fiber optic cable, you must do the 
following to become synchronized with the CST Master:
• Stop all motion connected to this chassis.
• Reset the 1756-SYNCH module via application ladder logic 
or RSLogix 5000.
Dependence on SynchLink is Ignored
• The module is a Time Slave on SynchLink.
• The module is the CST Time Master of the local chassis.
• You MUST have selected another module on the backplane 
to be the SynchLink CST Master.
• The module acts as an unsynchronized Chassis CST Master.
In this case, the module ignores the SynchLink CST Master 
at all times, including module power-up.
This option is expected to be a temporary mode of 
operation.
Table 3.7 Possible SynchLink Configurations
This configuration:
Means: