Using remote axis control, Configure time master chassis - master node – Rockwell Automation 1756-SYNCH ControlLogix SynchLink Module User Manual User Manual
Page 78
 
Publication 1756-UM521C-EN-P - July 2004
B-2 Configuring the Star Configuration
Using Remote Axis Control
Most applications using the ControlLogix SynchLink module use it for 
Remote Axis Control. You can use the SynchLink module to produce axes 
from a master chassis and broadcast the data to other chassis.
Slave chassis consume the broadcast axis data and redistribute it to their local 
motion planners (i.e. the Logix controller in their local chassis). With this 
configuration, you can control multiple axes synchronously throughout the 
system.
Configure Time Master Chassis - Master Node
You must complete the following tasks to configure the time
master chassis.
• Create a New RSLogix 5000 Project
• Add a SynchLink Module
• Configure the SynchLink Module
– Name the module
– Choose a receive communications format
– Choose a transmit communications format
– Choose an electronic keying option
– Set the RPI
– Determine if the module is the CST Time Master for
the chassis
– Make the module the Time Master for the SynchLink
• Download Configuration
IMPORTANT
This example assumes you have already set-up axis data 
tags for the data the controller in the Time Master chassis 
produces; this manual does not intend to explain how to 
plan the motion portion of your application as that is a 
controller function.
If you do not know how to set-up remote axis data tags and 
account for them in the motion portion of your 
application, see the ControlLogix Motion Module Setup & 
Configuration User Manual, publication 1756-6.5.16.
Time Master Chassis
ControlNet
SynchLink
Hub