Publication 4100-5.3 - June 1999

14 Installation & Hook-Up

See the “Setup” Chapter in this manual for instructions on setting these
switches.

The following section details how to wire the :

AxisLink cable

Incremental Encoder

Registration Input

Power connector

Fault Relay

Wiring the ALEC

There are several connectors on the front of the ALEC. These
connectors accept the cables from AxisLink (3 pin), the Encoder (12
pin), the Registration Sensor (3 pin), the power supply (top 2 pins of
the 4 pin connector), and a Fault Relay (bottom 2 pins of the 4 pin
connector). All but the Encoder connector use flying leads to attach to
the connector. The following section details how to connect the flying
leads to the screw terminals on the plugs.

Wiring Cable Flying Leads to the Plugs

To wire the cable leads to the plug:

1. Look at the plug to make sure the terminal is open. Figure 2.2

shows both an open and a closed terminal.

Figure 2.2 Terminal diagram

Terminal open

Terminal closed

Clamping screws