Connecting the encoder – Rockwell Automation 4100 ALEC AXIS LINK ENCODER CONVERTER User Manual

Page 25

Advertising
background image

Publication 4100-5.3 - June 1999

Installation & Hook-Up 17

Connecting the Encoder

Encoders are connected to the ALEC using a supplied cable assembly.
Two encoder cable assemblies are available as shown in the following
table.

The encoder cable assemblies shown in the preceding table are
electrically identical. The only difference is their length.

Connect the encoder to the ALEC encoder cable assembly as shown in
the following diagram.

Figure 2.4 Wiring diagram for connecting the Encoder to the ALEC

Plug the other end of the encoder cable assembly into the
Incremental Encoder Input connector on the front panel of the ALEC.

The encoder power supply in the ALEC provides 5 or 12 volts DC for
powering the encoder. Voltage selection is by DIP switch 1 on the
front panel. Push the switch all the way to the left for 12V encoders or

Table 2.3 ALEC Encoder Cable Assemblies

Order Number

Length

4100-CAE15

15 feet (4.5 meters)

4100-CAE30

30 feet (9 meters)

IMPORTANT

Anchor the cable so that no more than 2 feet of cable is
left unsupported. The excessive weight of an unanchored
cable could pull the plug out of the connector.

Incremental Encoder

White

Black
Green

Black

Blue

Black

Red

Black

A +

A -

B +
B -

Z +
Z -

Power
Com