Extended versus standard axislink, Allen-bradley 845 encoders – Rockwell Automation 4100 ALEC AXIS LINK ENCODER CONVERTER User Manual

Page 39

Advertising
background image

Publication 4100-5.3 - June 1999

Setup 31

Extended versus Standard AxisLink

AxisLink has two modes of operation: Standard and Extended. In
standard mode the maximum AxisLink cable length for the connected
modules is limited to 85 feet (25 meters). In extended mode modules
can be connected as needed on the AxisLink cable for up to 410 feet
(125 meters). The number of modules that can be connected to
AxisLink is limited to 8 in standard addressing mode where in
extended addressing mode 16 modules may be connected.

Allen-Bradley 845 Encoders

If you are using and Allen-Bradley 845 series incremental encoder, use
the following table to determine the proper setting of the Mode Switch
and DIP Switch 1.

Table 3.2 AxisLink Cable Length and Node Combinations

Extended/
Standard
Length

Extended/
Standard
Address

Maximum
Cable Length

Maximum
Number of
Nodes

Standard

Standard

25 meters
(82 feet)

8

Extended Standard

125

meters

(410 feet)

8

Extended

Extended

125 meter
(410 feet)

8

Extended

Extended

100 meters
(328 feet)(

12

Extended

Extended

75 meters
(246 feet)

16

ATTENTION

!

The maximum values for both AxisLink cable length and
the number of available Address nodes, with both
Extended Length and Extended Node selected, were
determined under controlled test conditions. These
values may vary due to field conditions. Allen-Bradley
cannot guarantee these optimal values under field
conditions.

Advertising