Micro810 Controllers
General – 2080-LC10-12AWA, 2080-LC10-12QWB, 2080-LC1012DWD, 2080-LC10-12QBB
Attribute
2080-LC10-12AWA
2080-LC10-12QWB
2080-LC1012DWD
2080-LC10-12QBB
Number of I/O
8 Input (4 digital, 4 analog/digital, configurable)
4 Output
Dimensions
HxWxD
91 x 75 x 59 mm
(3.58 x 2.95 x 2.32 in.)
Supply voltage range
85…263V
20.4…26.4V DC
10.8V…13.2V DC
11.4V..26.4V DC
Supply frequency range
(AC supply)
47…63 Hz
–
Voltage range
100…240V AC, 50/60 Hz
24V DC
Class 2
12V DC
Class 2
12/24V DC
Class 2
Power consumption
5V A
3 W
I/O rating
Input: 120…240V AC
Input: 24V DC, 8 mA
Input: 12V DC, 8 mA
Input: 24V DC, 8 mA
Output: 24V DC 1A, 25 °C, 24V DC
0.5A 55°C
Output: Relay 00 & 01: 8 A @ 240V AC, B300, R300, General Use
Relay 02 & 03: 4 A @ 240V AC, C300, R150, General Use
Shipping weight,
approx.
0.203 kg (0.448 lb)
Wire size
0.32... 2.1 mm² (22...14 AWG) solid copper wire or
0.32... 1.3 mm² (22...16 AWG) stranded copper wire
rated @ 90 °C (194 °F ) insulation max.
Wiring category
(1)
2 – on signal ports
2 – on power ports
Wiring torque
1.085 Nm (8 lb-in.)
Wire type
use Copper Conductors only
Fuse, type
Rated 250V 3.15 A-RADIAL
Enclosure type rating
Meets IP20
North American temp
code
T5
Insulation stripping
length
7 mm (0.28 in.)
Isolation voltage
250V (continuous), Reinforced
Insulation Type, I/O to Aux and
Network, Inputs to Outputs.
Type tested for 60 s 3250V DC,
I/O to Aux and Network, Inputs
to Outputs
250V (continuous), Reinforced Insulation Type, I/O to
Aux and Network, Inputs to Outputs
Type tested for 60 s @ 720V DC, Inputs to Aux and
Network, 3250V DC Outputs to Aux and Network,
Inputs to Outputs
50V (continuous), Reinforced
Insulation Type, I/O to Aux and
Network, Inputs to Outputs
Type tested for 60 s @ 720V DC, I/O
to Aux and Network, Inputs to
Outputs
AC input filter setting
16 ms for all embedded inputs
(Through the Connected Components Workbench software, go to the Embedded I/O configuration window to re-configure the
filter setting for each input group
(1)