Chapter 7
Programming

7–5

The Keypad Module is not only capable of displaying numeric data, but also
alphanumeric messages to describe that data. These messages may be stored
in the programmable controller and sent to the Keypad Module via ASCII
code, or store up to 120 messages in the Keypad Module and trigger them
according to their message number. The later method is the most common
means of displaying messages on the Keypad Module.

As described earlier in the System Configuration section, several messages
have already been entered into the Keypad Module.

Figure 7.3 below shows Rung 2:2 has been added to the sample program.
This will trigger a message in the Keypad Module.

Figure 7.3

(CU)

Rung 2:0

F1

Function

Key

I:020

10

COUNTER UP

Counter

C5:1

Preset

69

Accum

50

CTU

(DN)

Rung 2:1

F1

Function

Key

I:020

10

MOV

Source

1

50

Dest

0:021

69

MOV

Rung 2:2

F1

Function

Key

I:020

10

MOV

MOV

Source

1

Dest

0:022

1

[

]

[

]

][

Triggering a Stored Message to
Describe Data