PanelView 1200 Terminal Functions

Chapter 2

2-18

23663

PASS-THROUGH

DOWNLOAD OPTIONS

>Auto Restart

>Address Source

>PLC Type

>Baud Rate

>Rack Number

>Starting Module

>Rack Size

>Last Chassis

>Module Group

>High/Low Byte

Up

Cursor

Save &

Exit

Manual

Address

Source

Down

Cursor

Change

Data

Yes

Application

PLCĆ5/250

230.4K

77

0

Full

Yes

7

High

Block

Transfer

Choosing Manual Address Source

will disable the Terminal's

current application file.

Select Application to enable.

On the keypad terminal, you can use the function keys to move the cursor.

F18 for Up Cursor

F19 for Down Cursor

F20 for Change Data

F21 for Save & Exit

Important On the keypad terminal, when Rack Number is selected and you
press the Change Data button, a keypad window opens. This window
disappears when you enter a valid rack number. On the touch screen
terminal, you can enter the Rack Number directly from the keypad when
Rack Number is selected. For both terminal types, the number must be in
Octal, and correspond to the PLC type selected.

Auto Restart

You can choose between Yes and No for the Auto Restart option. The
default is No.

If you choose Yes, PanelView 1200 will start executing the new

application file as soon as the download is completed.

If you choose No, PanelView 1200 will wait for operator confirmation

before it starts executing the new application.