Wire the external shunt module – Rockwell Automation 2090-SRxxx External Shunt Modules Installation Instructions User Manual

Page 15

Advertising
background image

Publication 2090-IN004B-EN-P — June 2008

External Shunt Modules 15

Wire the External Shunt Module

This section assumes you have mounted your external shunt module
and are ready to wire the shunt module power connections.

Refer to

Additional Resources

on

page 22

for the servo drive user

manual with the drive-end installation instructions.

Wire should be copper with 105

°

C (221

°

F) 600V minimum rating.

DC-bus Wiring Requirements

Follow these steps to wire your external shunt module.

1. Remove power from your drive system that includes the Bulletin

1394 or 2090 shunt module.

IMPORTANT

The National Electrical Code and local electrical codes take
precedence over the values and methods provided.

External Shunt
Cat. No.

Drive Module

Cat. No.

Shunt Module
Terminal
Connections

Recommended
Wire Size
mm

2

(AWG)

Torque Value
N•m (lb•in)

2090-SRxxx-xx

2098-xxx-HV030

2098-xxx-HV050

2098-xxx-HV100

COL

6 (10)

1.25 (11)

DC+

1394-SR9Ax,
1394-SR36Ax

2094-BSP2

1394x-SJT22-x

COL

8.4 (8)

2.5 (22.1)

DC+

ATTENTION

This system may have multiple sources of power. More than
one disconnect switch may be required to de-energize the
system. To avoid shock hazard or personal injury, verify that all
power has been removed before proceeding.

ATTENTION

This product contains stored energy devices. To avoid hazard
of electrical shock, verify that all voltage on the capacitors has
been discharged before attempting to service, repair, or
remove this unit. You should only attempt the procedures in
this document if you are qualified to do so and familiar with
solid-state control equipment and the safety procedures in
publication NFPA 70E.

Advertising