External Shunt Modules 7

Noise Zones for Kinetix 6000 Drives

Observe these guidelines when mounting your external shunt module
outside the enclosure:

Mount circuit components and wiring in the very dirty zone or
in an externally shielded enclosure. Run shunt DC-bus and fan
wiring inside metal conduit to minimize the effects of EMI and
RFI.

Mount resistors (other than metal-clad) in a shielded and
ventilated enclosure outside the cabinet.

Keep unshielded wiring as short as possible. Keep shunt DC-bus
wiring as flat to the cabinet as possible.

Route thermal switch and fan wires separate from shunt DC-bus.

External Shunt Module Mounted Outside the Enclosure

C

D

D

D

D

D

VD

C

VD

D

1394 Digital Servo Controller

300W Shunt Module

BULLETIN 1394 300W SHUNT MODULE

ALLEN-BRADLEY

FOR USE WITH 1394-SJT22-X SYSTEM MODULE

CAT.

PART

SER.

INPUT DC

INPUT AC

FOR FUSE REPLACEMENT USE:
BUSSMAN CAT. NO.

R

(1)

Line Interface Module

Kinetix 6000

Drive System

Dirty Wireway

Clean Wireway

Motor Power Cables

Very Dirty Connections Segregated

(not in wireway)

Customer-supplied

Metal Enclosure

150 mm (6.0 in.)

clearance, min on all four

sides of the shunt module.

Enclosure

2094-BSP2

Shunt Module

Shunt DC-bus Wiring Methods:

Twisted pair in conduit (1st choice).

Shielded twisted pair (2nd choice).

Twisted pair, two twists per foot, min (3rd choice).

Metal Conduit

(where required

by local code)

I/O and Feedback Cables

Shunt Thermal Switch and Fan Wires (when present)

No sensitive

equipment within

150 mm (6.0 in.).

Route 24V DC I/O

shielded cable.

Route encoder/analog/registration

shielded cables.

Advertising