16 External Shunt Modules

2. Prepare the shunt DC-bus wires for attachment to the shunt

power terminals by removing 10 mm (0.39 in.) of insulation.

3. Insert one wire into the shunt power terminal labeled COL.

4. Insert the other wire into the shunt power terminal labeled DC+.

5. Tighten both screw terminals.

Refer to torque values in the table on

page 15

.

6. Gently pull on each wire to make sure it does not come out of

its terminal; reinsert and tighten each loose wire.

Shunt Module Terminations

(1)

Shunt module is shown with front cover open.

(2)

Shunt module is shown with front cover removed.

(3)

Only the 1394-SR36AF shunt module has the fan and thermal switch connections.

IMPORTANT

Use caution not to nick, cut, or otherwise damage strands as
you remove the insulation.

Shunt Power

Connector

1394-SR36Ax and

2090-SR040-18

External Shunt Modules

(2)

1394-SR9Ax,

2090-SR120-09,

and 2090-SR040-09

External Shunt Modules

(1)

Shunt Power

Connector

Shunt Fan

(3)

Connector

Thermal Switch

(3)

Terminal Block

Advertising