Rockwell Automation 2090-SRxxx External Shunt Modules Installation Instructions User Manual
Page 16

Publication 2090-IN004B-EN-P — June 2008
16 External Shunt Modules
2. Prepare the shunt DC-bus wires for attachment to the shunt
power terminals by removing 10 mm (0.39 in.) of insulation.
3. Insert one wire into the shunt power terminal labeled COL.
4. Insert the other wire into the shunt power terminal labeled DC+.
5. Tighten both screw terminals.
Refer to torque values in the table on
page 15
6. Gently pull on each wire to make sure it does not come out of
its terminal; reinsert and tighten each loose wire.
Shunt Module Terminations
(1)
Shunt module is shown with front cover open.
(2)
Shunt module is shown with front cover removed.
(3)
Only the 1394-SR36AF shunt module has the fan and thermal switch connections.
IMPORTANT
Use caution not to nick, cut, or otherwise damage strands as
you remove the insulation.
Shunt Power
Connector
1394-SR36Ax and
2090-SR040-18
External Shunt Modules
(2)
1394-SR9Ax,
2090-SR120-09,
and 2090-SR040-09
External Shunt Modules
(1)
Shunt Power
Connector
Shunt Fan
(3)
Connector
Thermal Switch
(3)
Terminal Block