Rockwell Automation 2090-SRxxx External Shunt Modules Installation Instructions User Manual
Page 18
Advertising
Publication 2090-IN004B-EN-P — June 2008
18 External Shunt Modules
4. Insert the jumper wires that came with your shunt module to
support the input power used in your application.
5. Insert one wire from the AC power supply into terminal 1.
6. Insert the other wire from the AC power supply into terminal 4.
7. Tighten all screw terminals.
8. Gently pull on each wire to make sure it does not come out of
its terminal; reinsert and tighten any loose wires.
1
2
3
4
1
2
3
4
To Power Supply
To Power Supply
To Power Supply
To Power Supply
Wiring the Fan for 115V
Wiring the Fan for 115V
IMPORTANT
When tightening screws to secure the wires, refer to the table
for torque values.
Advertising