Wire the shunt module fan – Rockwell Automation 2090-SRxxx External Shunt Modules Installation Instructions User Manual

Page 17

Advertising
background image

Publication 2090-IN004B-EN-P — June 2008

External Shunt Modules 17

Wire the Shunt Module Fan

This procedure applies to only the 1394-SR36AF shunt module and
assumes that you have mounted the module and wired the shunt
DC-bus connections.

Refer to

Additional Resources

on

page 22

for the servo drive user

manual with the drive-end installation instructions.

You can wire the shunt fan connections for 115V or 230V AC input
power. Wire should be copper with 75

°

C (167

°

F) minimum rating.

Fan Power Specifications

Fan Power Wiring Requirements

Follow these steps to wire the shunt fan.

1. Verify that all power is removed from the system.

2. Open the front door of the shunt module.

3. Using a screwdriver, remove the plate that covers the fan wire

access hole on the bottom right side of the module.

Refer to the figure on

page 16

for the location of the fan power

terminal block.

Input Power

Current

115V AC

0.2 A

230V AC

0.1 A

IMPORTANT

If you mount the shunt module outside the cabinet, the shunt fan
power wiring must be inside metal conduit to minimize the levels of
EMI and RFI.

External Shunt Module
Cat. No.

Fan Terminal Connections

Recommended
Wire Size
mm

2

(AWG)

Torque Value
N•m (lb•in)

Pin

Voltage
(V AC)

1394-SR36AF

1

115, 230

1.3 (16)

0.6 (6)

4

115, 230

1…3

115

2…4

115

2…3

230