7--12

Using ODS Communication Configuration

Publication 8520--UM051A--EN--P -- October 2000

Offline Development Manual (ODS) Software User Manual

Refer to Figure 7.10 to see the menu flow used to configure RSLinx
for Ethernet.

Figure 7.10

Configuration Flow for Using RSLinx for Ethernet (CNCs only)

1.

2.

RSLinx for Ethernet

RSLinx Station Address

of 9/Series

AB_ETH

Driver Number

Select the appropriate driver number for your configuration

This number corresponds to the AB_ETH driver configured in

RSLinx for Ethernet communication. The driver range is 01 to

64 (decimal). The default value is 01.

Select the station address that was mapped to the 9/Series control’s

IP address during RSLinx configuration. The address range is 0 to

63 (decimal). The default value is 0.

After you edit and save your AMP file, download it to the 9/PC so
that it is the currently active AMP file. You can use ODS to
download AMP files three ways:

from the local host PC into the 9/PC (refer to page 5--3)

from a separate network--connected ODS workstation that is
running Windows NT to the host PC and into the 9/PC card

from an ODS workstation running Microsoft Windows NT and
Dial--up Networking, connected to the serial port of the host PC
running Microsoft’s’ Remote Access Services (RAS), and into the
9/PC card

In all cases, the information you enter when creating the project is
used to direct the download to the correct 9/PC for this project. This
includes the host PC name and the topic name of the 9/PC card. This
project information can be changed at any time.

Configuring RSLinx for

Ethernet

Downloading AMP Files

for Use with the 9/PC