What to do next – Rockwell Automation 8520-OM Offline Development System User Manual User Manual

Page 95

Advertising
background image

7--21

Using ODS Communication Configuration

Publication 8520--UM051A--EN--P -- October 2000

Offline Development Manual (ODS) Software User Manual

9. Start the RAS server on the 9/PC Host (server PC) if you did not

already do so in the last section:

A. Click the Windows NT Start button and select Settings.

B. Select Control Panel.

C. Double click the Services control panel to view the available

services.

D. Locate and highlight the Remote Access Server. Click

Start.

10.Click Dial to connect to the 9/PC host (server PC) from your

ODS workstation (client PC).

Troubleshooting Tips for RAS Configuration

If you receive the message “Error 651” when establishing a
connection, the first items to check are:

cable pinouts are correct and have continuity

Cable connections are good to the PC serial ports

The port you have connected the cable to actually corresponds to
the port name you have configured (e.g.,COM1 vs COM2).

Baud rates and other port settings for the configured ports must
be the same on the client and Server PCs

Baud rates up to 115,200 have been successfully used on short
cable lengths.

If you have any further questions after reading this manual, contact
Allen-Bradley Software Support Services at (440) 646-6800.

END OF CHAPTER

What to Do Next