Rockwell Automation 9220-KTCT INSTL.INSTR CONTROLNET ISA/EISA User Manual

Page 10

Advertising
background image

ControlNet ISA/EISA Bus Tool Installation Instructions

10

9220-5.1 — November 1996

Setting the Card’s Switches

!

ATTENTION: This card uses CMOS technology, which
is highly sensitive to electrostatic discharge (ESD). ESD
may be present whenever you are handling this card.

Handling this card without any ESD protection can cause
internal circuit damage that may not be apparent during
installation or initial use. A grounding wrist strap has been
shipped with the 9220-KTCT to be worn during the
installation procedure. Instructions for use of the strap are
found on the back of its package.

Take these precautions to guard
against ESD damage:

Before handling the card, be sure
to wear the provided static strap and
touch a grounded object to discharge
any built-up static charge.

Avoid touching the backplane connector or
interface connector pins located on the card.

If the card is not in use, store it in the static bag
that the card was shipped in.

Important:

Remember, a computer with ac power
disconnected is not a grounded object.

wrist-strap
grounding
device

Important:

When selecting configuration settings, check for conflicts
with other interface card and system memory. If there is a
conflict, the host computer will not operate properly.

If you have a 386, 486, or Pentium host computer, you must
disable caching and shadow memory for at least the 16K
of memory space occupied by each 9220-KTCT card.
This can usually be accomplished through your CMOS
setup program or memory manager, and must be done
before running applications with the 9220-KTCT card.

Advertising