Running the installation check utility – Rockwell Automation 9220-KTCT INSTL.INSTR CONTROLNET ISA/EISA User Manual
Page 15

ControlNet ISA/EISA Bus Tool Installation Instructions
15
9220-5.1 — November 1996
Running the Installation Check Utility
Run the installation check utility before you connect the card to the
network to make sure the card has been properly installed.
1. Place the utility disk, that is shipped with the card, in drive A of the
host computer.
If you are running the utility software from
another drive, use the appropriate drive letter.
2. At the DOS prompt, type:
a:\ktctinst
Return
You see a screen similar to this one:
9220-KTCT Card Installation Check Utility
Version 1.0 — 21-Oct-96
Copyright
E
1996 Allen-Bradley Company, Inc.
Usage: KTCTINST NetworkAddress [IOaddress]
NetworkAddress = KTCT Network Address, in hex
IOaddress
= KTCT I/O base address (Default 220), in hex
In order to run the KTCT installation utility, you must specify the
network address and the I/O address, if other than 220.
For a network address of 3 and I/O address of 260, type:
KTCTINST 3 260
For a network address of 2 and I/O address of 220 (default), type:
KTCTINST 2
C:\
3. Type:
a:\ktctinst 2
Return
(where 2 is the network address you’ve selected)
You see:
Warning.. Make sure that the card is not connected to a network. Press any key.