Rockwell Automation 2100-GK61 DeviceNet to SCANport User Manual
Page 149

Publication 2100-UM001B-EN-P – January 2001
DeviceNet to SCANport Communication Module with Digital Inputs Parameters
B-23
39
Peer B Output
Off
Cmd/Ref
DL A Input
DL B Input
DL C Input
DL D Input
DL A Output
DL B Output
DL C Output
DL D Output
Off
Yes
No
Determines the source of peer B output data in
the SCANport product.
Important: This parameter cannot be changed
when the Peer Out Enable (40) parameter is On.
40
Peer Out
Enable
On, Off
Off
Yes
No
Off = Disables peer output communications.
On = Enables peer output communications.
41
Peer Out Time
0.01 – 10.00
1.00
Yes
No
Determines the minimum interval of time
between peer transmissions.
42
Peer Out Skip
1 – 16
1
Yes
No
Determines the maximum interval of time
between peer transmissions by multiplying this
value by the value in the Peer Out Time (41)
parameter.
#
Name
Valid Values/
Settings
Default
Writable
Reset or
Power
Cycle
Description
Important:
For information on accessing and editing parameters, refer to Chapter 3, Configuring the DeviceNet to SCANport
Communication Module with Digital Inputs.