Figure 4.3 – typical schematic (sheet 2 of 3), 10 setup and commissioning – Rockwell Automation 1901 SyncPro User Manual

Page 36

Advertising
background image

4-10

Setup and Commissioning

1901-UM020C-EN-P – June 2013

MOV

SLOT 0

5/03 CPU

C

BLK

#14 WIRE

BLK

W

R

F3

L

1

12

W

R

+

-

R

20 kOHM

20 kOHM

1

1

2

3

4

5

6

7

8

9

10

12

12

C3A

C3B

20

26

27

28

29

30

31

32

33

34

35

36

37

1747-C10

12

20

26

1

GRD

NEUT

VAC

120VAC

COM

24VDC

1746-P1

V

N

C

P

TB2

G

F2

F1

TB1

C

BLK

R

W

BLK

RF1

RF2

DC COM

DC COM

IN 1

IN 0

IN 2

IN 3

IN 4

IN 5

IN 6

IN 7

IN 8

IN 9

IN 10

IN 11

IN 12

IN 13

IN 14

IN 15

1

5

6

7

9

10

C3A

C3B

20

1

31

10

7

5

5

5

4

7

TRIP/RESET

DOOR EQUIPMENT

(REAR VIEW) ON

ENCLOSED UNITS

DTAM

1474-DTAM-E

GROUND

BAR

POWER

SUPPLY

(Remove Jumper
If present)

Battery

SLOT 1

24 VDC Input

1746-IB16

ANALOG/DIGITAL BOARD

MOV

SLOT 0

5/03 CPU

C

BLK

#14 WIRE

BLK

W

R

F3

L

1

12

W

R

+

-

R

20 kOHM

20 kOHM

1

1

2

3

4

5

6

7

8

9

10

12

12

C3A

C3B

20

26

27

28

29

30

31

32

33

34

35

36

37

1747-C10

12

20

26

1

GRD

NEUT

VAC

120VAC

COM

24VDC

1746-P1

V

N

C

P

TB2

G

F2

F1

TB1

C

BLK

R

W

BLK

RF1

RF2

DC COM

DC COM

IN 1

IN 0

IN 2

IN 3

IN 4

IN 5

IN 6

IN 7

IN 8

IN 9

IN 10

IN 11

IN 12

IN 13

IN 14

IN 15

1

5

6

7

9

10

C3A

C3B

20

1

31

10

7

5

5

5

4

7

TRIP/RESET

DOOR EQUIPMENT

(REAR VIEW) ON

ENCLOSED UNITS

DTAM

1474-DTAM-E

GROUND

BAR

POWER

SUPPLY

(Remove Jumper
If present)

Battery

SLOT 1

24 VDC Input

1746-IB16

ANALOG/DIGITAL BOARD

Figure 4.3 – Typical Schematic (Sheet 2 of 3)

Advertising