Figure 4.3 – typical schematic (sheet 3 of 3), Setup and commissioning 4-11, Sw1 2 1 – Rockwell Automation 1901 SyncPro User Manual

Page 37

Advertising
background image

Setup and Commissioning

4-11

1901-UM020C-EN-P – June 2013

Figure 4.3 – Typical Schematic (Sheet 3 of 3)

BLK

C

3

26

27

28

29

30

32

31

6

8

33

34

35

2

4

36

37

5

6

1

7

FCR

SS

9

5

ESR

SS

12

1

31

5

6

4

3

1

2

7

8

20

12

1

OUT 0

VAC 0

VAC 1

OUT 1

VAC 2

OUT 2

VAC 3

OUT 3

VAC 4

OUT 4

VAC 5

OUT 5

VAC 6

OUT 6

VAC 7

OUT 7

NOT

USED

NOT

USED

USED

NOT

USED

NOT

IN0+

IN0-

ANLCOM

IN1+

IN1-

ANLCOM

OUT 0

ANLCOM

ANLCOM

OUT 1

AC COM

AC COM

IN 15

IN 14

IN 13

IN 12

IN 11

IN 10

IN 9

IN 8

IN 7

IN 6

IN 5

IN 4

IN 3

IN 2

IN 0

IN 1

31

1

20

C3A

C3B

10

9

6

7

5

1

10

3

5

SLOT 4

120 VAC INPUT

1746-IA16

SLOT 3

120 VAC RELAY OUTPUT

1746-OX8

PHASE ANGLE

TRANSDUCER

SLOT 2

INPUT/OUTPUT MODULE

1746-NI041

FCR RELAY

TRIP (NOT FAULTED)

OPTIONAL SCP TRIP
PILOT LIGHT

OPTIONAL MOTOR
PULLOUT TRIP
PILOT LIGHT

OPTIONAL INCOMPLETE
SEQUENCE TRIP
PILOT LIGHT

RUN

AUTOLOAD

COMMONS

CONNECTED
INTERNALLY

MAIN CONTACTOR

M

FEEDBACK CONTACTOR

NOT STOP

START

RESET

FIELD VOLTAGE RELAY

M

FIELD CONTACTOR

M

FEEDBACK CONTACTOR

SYNCHRONIZATION ENABLE INPUT

MN

(TRANSITION COMPLETE)

FIELD LOSS RELAY (CURRENT)

MN

EQUIPMENT SHUTDOWN RELAY INPUT
(RESET PERMITTED)

BLK

C

3

26

27

28

29

30

32

31

6

8

33

34

35

2

4

36

37

5

6

1

7

FCR

SS

9

5

ESR

SS

12

1

31

5

6

4

3

1

2

7

8

20

12

1

OUT 0

VAC 0

VAC 1

OUT 1

VAC 2

OUT 2

VAC 3

OUT 3

VAC 4

OUT 4

VAC 5

OUT 5

VAC 6

OUT 6

VAC 7

OUT 7

NOT

USED

NOT

USED

USED

NOT

USED

NOT

IN0+

IN0-

ANLCOM

IN1+

IN1-

ANLCOM

OUT 0

ANLCOM

ANLCOM

OUT 1

AC COM

AC COM

IN 15

IN 14

IN 13

IN 12

IN 11

IN 10

IN 9

IN 8

IN 7

IN 6

IN 5

IN 4

IN 3

IN 2

IN 0

IN 1

31

1

20

C3A

C3B

10

9

6

7

5

1

10

3

5

SLOT 4

120 VAC INPUT

1746-IA16

SLOT 3

120 VAC RELAY OUTPUT

1746-OX8

PHASE ANGLE

TRANSDUCER

SLOT 2

INPUT/OUTPUT MODULE

1746-NI041

FCR RELAY

TRIP (NOT FAULTED)

OPTIONAL SCP TRIP
PILOT LIGHT

OPTIONAL MOTOR
PULLOUT TRIP
PILOT LIGHT

OPTIONAL INCOMPLETE
SEQUENCE TRIP
PILOT LIGHT

RUN

AUTOLOAD

COMMONS

CONNECTED
INTERNALLY

MAIN CONTACTOR

M

FEEDBACK CONTACTOR

NOT STOP

START

RESET

FIELD VOLTAGE RELAY

M

FIELD CONTACTOR

M

FEEDBACK CONTACTOR

SYNCHRONIZATION ENABLE INPUT

MN

(TRANSITION COMPLETE)

FIELD LOSS RELAY (CURRENT)

MN

EQUIPMENT SHUTDOWN RELAY INPUT
(RESET PERMITTED)

M

Customer supplied equipment.

N

FLR and TC are optional customer supplied inputs which
are jumpered to terminal blocks, if not used.

O

Contact rating is 60 amp Make, 10 amp Break (inductive)
– 10 amp continuous at 120 V AC (A600).

P

Refer to instruction manual for tap selection guidelines on
R

F

1 and R

F

2 resistors.

Q

Analog card switch settings are:

R

Customer to take ground wire to ground bus (earth ground).

S

Ground at bottom left hand mounting screw for rack or
grounding bar.

T

Line 1 to Line 2 voltage reference and Line 3 current reference
must be maintained for proper operation of the phase angle
transducer.

U

Wiring supplied on enclosed assembly only (1901-AADC10)
for the open frame units. The customer must supply these
wires in addition to mounting the illuminated push button.
DTAM, STAM cable (1747-C10) and illuminated push button
are supplied loose on open frame assemblies. (1901-ANDC10)

SW1

2 1

ON
OFF