3.

Loop the wires through the ferrite.

4.

Close the ferrite.

Be careful not to damage the wires.

5.

Strip approximately 6 mm (0.24 in.) of wire from the end that will connect
to the relay contact connector on the 1786-RPFRL/B or
1786-RPFRXL/B module.

6.

Remove the relay contact connector from the 1786-RPFRL/B or
1786-RPFRXL/B module.

7.

Install the stripped ends of the wires in the relay contact connector on the
fiber repeater module as shown below.

8.

Reinsert the relay contact connector into the 1786-RPFRL/B or
1786-RPFRXL/B module.

9.

Connect the fiber cable as described on

page 66

.

10.

If you plan not to use a channel, attach a small section of fiber cable (or a
Simplex fiber loop) between the Receive port (RX) and the Transmit port
(TX) of any unused fiber port to create a jumper.

Although not required for module operation, the jumper turns the status
indicators green and prevents the relay contact connector from opening
and indicating a failure.