Instances, Instance attributes, Instances instance attributes – Rockwell Automation 1440-VAD02-01RA XM-123 Aeroderivative Module User Manual
Page 131

Publication GMSI10-UM003D-EN-P - May 2010
123
Instances
There are 2 instances of this object.
Instance Attributes
Table C.30 Band Measurement Object Instances
Instance
Description
1
Channel 1 Band Measurement
2
Channel 2 Band Measurement
Table C.31 Band Measurement Object Instance Attributes
Attr ID
Access
Rule
Name Data
Type
Description
Semantics
3
Get
Band Value
REAL
The measured band value. See Data Units
4
Get
Status
BOOL
Indicates if a fault or
alarm has occurred.
0 = Operating without alarms or
faults
1 = Alarm or fault condition
exists, the Band Value
attribute may not represent the
actual field value.
5
Get
Data Units
ENGUNIT
The units context of the
Band Value attribute.
This attribute is read only. It is
set according to the Output
Data Units attribute of the
associated Channel Object
instance. See page 125.
7
Get/Set
Minimum
Frequency
REAL
The minimum frequency
that is included in the
band measurement.
25 to 1000 Hz
8
Get/Set
Maximum
Frequency
REAL
The maximum frequency
that is included in the
band measurement.
100 to 5500 Hz
The Maximum Frequency must
be greater than or equal to
Minimum Frequency.