Microsoft MSDN site for SQL Server 2005 collation settings. (Internet addresses are
subject to change without notice.)

Unable to log on to SQL Server Express during server
installation

The logon during the installation process requires the use of the SQL Server Express sa
(system administrator) account. If you configured your SQL Server to use mixed (both
SQL Server and Windows domain) authentication, the sa account is available. Use the
password you created for the sa account when the installation program prompts you for it.
If your SQL Server Express installation is not configured for mixed authentication, you
will need to change the authentication method. See the documentation for SQL Server
Express for more information.

If you have forgotten your sa account password, you will need to change it. See the
Microsoft SQL Server Express documentation for more information.

Starting FactoryTalk AssetCentre Machine Edition

“Cannot initialize application eventing subsystem” or “No
connection could be made because the target machine
actively refused it” appears when starting the software

If you see the error “Cannot initialize application eventing subsystem” or an error
indicating that the target machine actively refused the connection, then:

„

Make sure the FactoryTalk AssetCentre Server service is started.

„

Reboot the computer. If you still see the error, then:

„

Stop and disable all schedules. Reboot the computer.

“At least one service or driver failed during system startup.
Use Event Viewer to examine the event log for details”
appears when starting the software

This message may appear when launching RSLinx Classic on a computer that has both
RSLinx Classic and RSLinx Enterprise installed. The System Event log contains the
message, “The A-B Virtual Backplane service failed to start due to the following error:
The system cannot find the file specified.”

In some cases, the Virtual Backplane driver does not get installed correctly. For more
information see the Rockwell Automation Knowledgebase article 34128
(

http://www.rockwellautomation.com/knowledgebase/

).