Rockwell Automation FlexPak Plus NRG DC Drive User Manual
Page 12
11
Notes:
1> These signals must be run in a separate magnetic conduit to
minimize the possibility of noise pickup. (Refer to Table 7.B for
wire specifications.)
2> Remove the connection between SPEED pot and terminal 426
when AUTO/MANUAL switch is used.
3> Motors with dual voltage shunt fields should be connected for
the rated controller voltage.
4> Remove jumper J9 from Regulator Module when Reversing
Contactor is installed.
5> Use convenience terminals for #14 AWG maximum wire size.
6> If auxiliary Panel is not used, user must supply an appropriate
M contactor. Refer to Paragraphs 2.4.4 and I/M D3955.
Process Control
or
Auto Reference
Inputs
Instrument Interface
or
VoltageFollower Kit
Tachometer Feedback Kit
REMOTE OPERATOR
INTERFACE
REMOTE OPERATOR CONTROLS
Tachometer
DĆC DriveMotor
3ĆPHASE
PLANT POWER
SPEED Pot
AUTO/
MANUAL
switch
No
Number
TORQUE Pot
No
Number
JOG/RUN
switch
FWD/REV
switch
START/STOP
switch
Figure 3.4 - System Connection Diagram