Rockwell Automation FlexPak Plus NRG DC Drive User Manual

Page 8

Advertising
background image

7

WARNING

IN THE OPTIONAL BASIC DRIVE, THE USER

MUST INSTALL AN M CONTACTOR THAT HAS

A 115 VAC COIL WITH A MAXIMUM CURRENT

DRAW OF 440 MILLIAMPS. THE CONTACTOR

ADAPTER KIT MUST BE INSTALLED WITH THE

USER'S M CONTACTOR. (REFER TO DĆ3955)

PERSONAL INJURY MAY OCCUR IF THIS IS

NOT INSTALLED.

2.4.5 AĆC Line Fuse Requirements - AĆC line protecĆ

tion is provided with the Auxiliary Panel. The Optional

Basic FlexPak Controller, however, does not include aĆc

line protection. Fused aĆc line protection must be used.

Refer to Table 2.C for proper fuse sizing. (Note: SemiĆ

conductor current limiting fuses must be used.)

Table 2.C - Fuse Requirements

HP

AĆC

Line

Fuse Specification

(one per Phase)

HP

Line

Volts

Reliance

Part No.

Rating

3Ć10

15

20

3Ć20

25Ć30

40

230

230

230

460

460

460

64676Ć12BX

64676Ć12CC

64676Ć12CC

64676Ć12BX

64676Ć12CC

64676Ć12CC

70A, 500V

125A, 500V

125A, 500V

70A, 500V

125A, 500V

125A, 500V

Table 2.D - DĆC Motor/Controller/Transformer Specifications

VAC

A C

D C

DĆC

Arm

D C

Amp

Power

Supply

Transformer

Controller

Model Numbers

HP

VAC

@

60 Hz

AĆC

Amps

(RMS)

DĆC

Arm.

(Volts)

Arm.

Amps

(avg.)

DĆC

Field

Volts

Amp.

Max.

Supply

Capacity

Maximum

kVA

Rated

kVA

14C300

3

5

7Ć1/2

10

230

230

230

230

12

20

28

36

240

240

240

240

12

20

29

38

150

150

150

150

5

5

5

5

5000

5000

5000

5000

ă30

ă50

ă63

ă80

ă6

10

12Ć1/2

16

14C301

15

230

51

240

55

150

5

5000

115

23

14C302

20

230

66

240

72

150

5

5000

145

30

14C303

3

5

7Ć1/2

10

15

20

460

460

460

460

460

460

ă7

11

14

18

26

34

500

500

500

500

500

500

ă6

10

14

18

27

36

300

300

300

300

300

300

5

5

5

5

5

5

5000

5000

5000

5000

5000

5000

ă30

ă50

ă63

ă80

115

145

ă6

10

12Ć1/2

16

23

30

14C304

25

30

460

460

40

47

500

500

43

51

300

300

5

5

5000

5000

175

205

35

41

14C305

40

460

63

500

69

300

5

5000

250

55

Because of nature of field loss protective circuitry, this supply must only be used for motor field excitation.

Maximum permissible available symmetrical RMS fault current with NEC or CEC external approved disconnect.

Drives have been designed for maximum of three units per maximum transformer rating.

Minimum required KVA size is 15 KVA for proper operation.

Advertising