6

Table 2.B - Specifications

AĆC Line input Voltage

230/460 VAC (nominal, 60 HZ)

220/440 VAC (nominal, 50 Hz)

three phase only

Line Voltage Variation

"10% of nominal

AĆC Line Frequency

Three Phase, 50/60 Hz

Line Frequency Range

48Ć62 Hz

Output Voltages

(armature and field)

See Table 2.D

ControllerĆDrive HP Range

3Ć20 (with 230 VAC input)

3Ć40 (with 460 VAC input)

Direction Control

Standard: Unidirection

Optionally: Forward/Reverse

Maximum Speed Adjustment

70 to 100% of base motor speed

(user adjustable)

Minimum Speed Adjustment

up to 30% of base motor speed

(user adjustable)

Operator Speed Adjustment

Infinitely adjustable with

optional control pot

(up to 100% of base speed)

Operator Torque Adjustment

Infinitely adjustable at optional control

pot

(10 to 150% of rated load)

IRDrop Compensation

0 to 12% of rated load

(user adjustable)

Controllable Speed Range

20:1

Current Limit

Factory shipped: 150% of full load

User adjustable: 10 to 150% of full load

Regulator (with 95% load change)

3 to 5% with voltage feedback

1.0% with specified tachometer feedback

0.5% with specified tachometer feedback

Minimum Load for Stable Operation

5%

Acceleration/Deceleration Rates

0.5 to 30 sec. linear time

(userĆadjusted separately)

Armature Circuit Overload Capacity

150% of armature current rating

for 1 minute (max.)

Efficiency (rated speed/rated load)

Controller only: 97%

Complete drive including

motor 85% (typical) ➀

Displacement Power Factor

68% (typical) ➀

Transient Protection

MOV and Output RC Circuit

Controller Service Factor

1.0

Duty

Continuous

Ambient Temperature

(storage and operational)

0

°

to 55

°

C (32

°

to 131

°

F)

Relative Humidity

(storage and operational)

5 to 95% (without condensation)

Operational Altitude

To 3300 ft (1000 m) above

sea level without derating

Controller Weight (approx.)

37 lb (87.8 Kg)

Controller Dimensions (LWD)

(A) = 18.75x10.62x8.00 in.

(476x270x203 mm)

(B) = 18.75x10.62x9.50 in.

(476x370x241 mm)

A - 3Ć10 HP/230V, 3Ć20 HP 460V

B - 15Ć20 HP/230V, 25Ć40 HP 460V

Typical percent shown. Exact figure dependent on motor base speed and frame size.

2.4 Specifications

- The more important specifiĆ

cations for the FlexPak Plus controller are listed in Table

2.B. Refer also to Table 2.D where other ratings are indiĆ

cated in relation to dĆc motors of specific horsepower.
2.4.1 Line Frequency - The FlexPak Plus controller is

able to operate without modification from a threeĆphase

power source having a frequency range from 48 to 62

Hz.
2.4.2 Voltage Tolerance - The FlexPak Plus controller

delivers output current and voltage, as listed in Table

2.D. It will also operate within these regulation specificaĆ

tions even with incoming line voltage at +/Ć10% of nomiĆ

nal.
2.4.3 Line Impedance Requirements - The FlexPak

Plus controller must be connected to a plant power supĆ

ply with maximum permissible available symmetrical

RMS fault current no greater than 5000 amperes. (Refer

to Table 2.D.)

WARNING

DO NOT OPERATE THE FLEXPAK PLUS CONĆ

TROLLER ON POWER SUPPLIES WITH AVAILĆ

ABLE SHORTĆCIRCUIT CURRENTS IN EXCESS

OF 5000 AMPERES. DAMAGE TO EQUIPMENT

AND PERSONAL INJURY MAY OCCUR. EXTERĆ

NAL DISCONNECT MEANS MUST HAVE ABILĆ

ITY TO INTERRUPT A 5000 AMP RMS CURRENT

FAULT.

2.4.4 Relay Control Circuit - The regulator board is

set up for use with 24 VDC main contactors having a coil

resistance greater than or equal to 100 ohms, 14C300

only; 14C301 to 14C305 is 1000 ohms. The control logic

sequences the contractor and the control relay on the

regulator so that current flow thru the main contactor is

never broken in normal operation by the contracts. ReĆ

fer to Figures 5.1, and 5.2.
The standard controller includes an M contactor. HowĆ

ever, the Optional Basic Controller does not have an M

contactor. An M contactor is required to provide positive

power disconnect in all applications.