Rockwell Automation FlexPak Plus NRG DC Drive User Manual

Page 14

Advertising
background image

13

HP/SCALING PINS

Figure 3.6 - Regulator Module, HP/Current Scaling Pins

Step 3 - On the Regulator Module, locate the scaling

pins. (Refer to Figure 3.6.) Near them, locate the black

pigĆtail type jumper. Do not move it if it is connected to

the proper pin. If it must be reconnected, carefully lift

connector housing straight up and off the pin. Slide the

connector straight down over the proper pin.

3.6 Regulation Mode

- The FlexPak Plus controlĆ

ler of drive regulation. The first, which is factory shipped,

is armature voltage feedback (A).
Optionally, the user may also use tachometer feedback

(T) regulation. In order to use this modes, however, the

Regulation Mode Jumper, one end of which is permaĆ

nently fixed to the Regulator Module, must be moved to

one of two positions. Details of jumper placement are

noted in Section 7, DĆ3969.

DANGER

IF YOU ARE UNSURE WHICH REGULATION

MODE A CONTROLLER SHOULD HAVE, IT IS

IMPORTANT YOU FIND OUT. IF THE JUMPER IS

NOT PROPERLY CONNECTED, PERSONAL INĆ

JURY MAY RESULT.