Rockwell Automation FlexPak Plus NRG DC Drive User Manual
Page 14
13
HP/SCALING PINS
Figure 3.6 - Regulator Module, HP/Current Scaling Pins
Step 3 - On the Regulator Module, locate the scaling
pins. (Refer to Figure 3.6.) Near them, locate the black
pigĆtail type jumper. Do not move it if it is connected to
the proper pin. If it must be reconnected, carefully lift
connector housing straight up and off the pin. Slide the
connector straight down over the proper pin.
3.6 Regulation Mode
- The FlexPak Plus controlĆ
ler of drive regulation. The first, which is factory shipped,
is armature voltage feedback (A).
Optionally, the user may also use tachometer feedback
(T) regulation. In order to use this modes, however, the
Regulation Mode Jumper, one end of which is permaĆ
nently fixed to the Regulator Module, must be moved to
one of two positions. Details of jumper placement are
noted in Section 7, DĆ3969.
DANGER
IF YOU ARE UNSURE WHICH REGULATION
MODE A CONTROLLER SHOULD HAVE, IT IS
IMPORTANT YOU FIND OUT. IF THE JUMPER IS
NOT PROPERLY CONNECTED, PERSONAL INĆ
JURY MAY RESULT.