Kinetix 3 (200v-class) drives with tl, Bulletin tl motor cable combinations – Rockwell Automation 2071-APx Kinetix 3 Drive Systems Design Guide User Manual

Page 14

Advertising
background image

14

Rockwell Automation Publication GMC-RM005B-EN-P - September 2013

Kinetix 3 Drive Systems

Kinetix 3 (200V-class) Drives with TL-Series (Bulletin TL) Low Inertia Motors

This section provides system combination information for the Kinetix 3 servo drives when matched with TL-Series
(Bulletin TL) low-inertia motors. Bulletin TL-A

xxx motors are equipped with absolute high-resolution encoder feedback

and are characterized as having 300 mm (11.8 in.) cable extensions with rectangular connectors. Included in this section are
motor power, feedback, and brake cable catalog numbers, system performance specifications, and the optimum torque/
speed curves.

Bulletin TL Motor Cable Combinations

For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on

page 7

.

Cable length xx is in meters. Refer to the Kinetix Motion Accessories Technical Data, publication

GMC-TD004

, for standard cable lengths.

Bulletin TL (non-brake) Performance Specifications with Kinetix 3 (200V-class) Drives

Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated line voltage. For additional
information on ambient and line conditions, refer to Motion Analyzer software.

Bulletin TL (brake) Performance Specifications with Kinetix 3 (200V-class) Drives

Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated line voltage. For additional
information on ambient and line conditions, refer to Motion Analyzer software.

Motor Cat. No.

Motor Power Cable

Motor Feedback Cable

(1)

(1) TL-Series (Bulletin TL) rotary motors require the 2071-TBMF breakout board with 3.6V lithium battery (not included) for multi-turn high-resolution encoder operation or when using an overtravel limit

switch. To meet this requirement, remove the drive-end connector and wire the 2090-DANFCT-Sxx cable to the 2071-TBMF breakout board. Refer to Kinetix 3 Motor Feedback Example (Bulletin TL motors)
on

page 4

for more information.

Motor Brake Cable

TL-A120P, TL-A130P

2090-DANPT-16Sxx

2090-DANFCT-Sxx
Absolute High-resolution

2090-DANBT-18Sxx

TL-A220P, TL-A230P

TL-A2540P

TL-A410M

Rotary Motor

Speed, max
rpm

System Continuous
Stall Current
A 0-pk

System Continuous
Stall Torque
N•m (lb•in)

System Peak
Stall Current
A 0-pk

System Peak
Torque
N•m (lb•in)

Motor Rated
Output
kW

Kinetix 3
200V-class Drives

TL-A120P

5000

1.03

0.181 (1.60)

2.50

0.36 (3.20)

0.086

2071-AP1

TL-A130P

1.85

0.325 (2.88)

4.90

0.76 (6.70)

0.14

2071-AP1

TL-A220P

3.50

0.836 (7.40)

7.90

1.48 (13.1)

0.35

2071-AP4

TL-A230P

5.50

1.30 (11.5)

15.5

3.05 (27.0)

0.44

2071-AP4

TL-A2540P

10.0 2.94

(26.0)

24.8 7.10

(63.0)

0.86 2071-AP8

TL-A410M

4500

15.5 5.42

(48.0)

43.4

13.0

(115.0)

2.0

2071-A15

Rotary Motor

Speed, max
rpm

System Continuous
Stall Current
A 0-pk

System Continuous
Stall Torque
N•m (lb•in)

System Peak
Stall Current
A 0-pk

System Peak
Torque
N•m (lb•in)

Motor Rated
Output
kW

Kinetix 3
200V-class Drives

TL-A120P

5000

0.93

0.163 (1.44)

2.50

0.36 (3.20)

0.077

2071-AP1

TL-A130P

1.67

0.293 (2.59)

4.90

0.76 (6.70)

0.13

2071-AP1

TL-A220P

3.15

0.757 (6.70)

7.90

1.48 (13.10)

0.24

2071-AP4

TL-A230P

4.95

1.160 (10.30)

15.5

3.05 (27.0)

0.32

2071-AP4

TL-A2540P

10.0

2.940 (26.00)

24.8

7.10 (63.0)

0.66

2071-AP8

TL-A410M

4500

14.0

4.860 (43.0)

43.4

13.0 (115.0)

1.80

2071-A15

Advertising