20

Rockwell Automation Publication GMC-RM005B-EN-P - September 2013

Kinetix 3 Drive Systems

Performance Specifications with Frame 150 Linear Thrusters

Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated line voltage. For additional
information on ambient and line conditions, refer to Motion Analyzer software.

Kinetix 3 (200V-class) Drives/LDAT-Series Integrated Linear Thruster Curves

Linear Thruster
Cat. No.

Velocity, max
230V AC
m/s

System Continuous
Stall Current
Amps 0-pk

System Continuous
Stall Force
N (lb)

System Peak
Stall Current
Amps 0-pk

System Peak
Stall Force
N (lb)

Rated Output
230V AC
kW

Kinetix 3
200V-class Drives

LDAT-S152010-DBx

LDAT-S152090-DBx

1.8

5.3

643 (145)

19.5

1799 (404)

0.87

2071-AP8

LDAT-S152010-EBx

LDAT-S152090-EBx

0.9

2.7

9.8

1679 (377)

0.34

2071-AP4

LDAT-S153010-DBx

LDAT-S153090-DBx

1.8

8.0

978 (220)

29.1

2680 (602)

1.33

2071-A10

LDAT-S153010-EBx

LDAT-S153090-EBx

1.8

10.7

1306 (294)

39.1

3597 (809)

1.78

2071-AP4

LDAT-S154010-DBx

LDAT-S154090-DBx

0.9

5.3

19.5

3383 (761)

0.70

2071-A15

LDAT-S154010-EBx

LDAT-S154090-EBx

1.8

16.3

1997 (449)

59.4

5469 (1229)

2.71

2071-AP8

LDAT-S156010-EBx

LDAT-S156090-EBx

0.9

8.1

19.8

5110 (1149)

1.05

2071-A10

2071-AP8 and LDAT-S031040-DBx

Velocity (m/s)

Force

(N)

Force
(lb)

200

175

150

125

100

75

50

25

0

45.0

39.3

33.7

28.1

22.5

16.9

11.2

5.6

0

0

2

4

3

1

= Intermittent operating region
= Continuous operating region

Advertising