Baumfolder BAUM 26_30: Folder 1st Station Contfeed User Manual

Page 21

Advertising
background image

PAGE 21 TP10476-1

P00: Input Counter
The number of sheets sensed by the sheet count sensor is multiplied by the factor number displayed, but does not
effect the Batch Down Count, Number of Batches and the Rate.
The Factor can range from 1 to 24. If the Input Factor is changed, it also changes the value of the Output
Counter to the same setting.

P01: Output Counter
This number is added to the Total Output Count but does not effect the Batch Down Count, Number of Batches
and the Rate.
The Factor can range from 1 to Input Counter setting.

P02: Tremat
This selection allows pile feeder machines to switch the tremat function on (1) and off (0)

P03: Knife
The operator must indicate to the machine whether a single cross-fold or several cross-folds are in use in the
machine network. This is done by entering either "1" (Cross fold) or "0" (No cross fold).
Entering "1" (Cross fold) automatically sets the sheet spacing to 10 cm after a single learned sheet. If "0" (No
cross fold) is entered, the sheet spacing is automatically set to 4 cm after a single learned sheet.

P04:Ergonomic stacking
Select "1" to activate the Ergonomic stacking function. "0" indicates that the Ergonomic stacking function is
disabled or not available.
Note: This parameter is only displayed on machines configured with a horizontal pile feeder.

P05: Kicker
Select this parameter to activate/deactivate the kicker function.
0 = Kicker disabled (not available), 1 = Kicker enabled.

2.1.2 DCT 500 Diagnostic Parameters

#

Function

Type

Variable Displayed

P10

Machine Speed

Statistics Values

Display only

Meters per minute

P11

Production time

Statistics Values

Reset to zero

Time in Hours (decimals)

P12

Production stoppage time Statistics Values

Reset to zero

Time in Hours (decimals)

P13

Setup time

Statistics Values

Reset to zero

Time in Hours (decimals)

P14

Pause

Statistics Values

Reset to zero

Time in Hours (decimals)

P15

Curent Job No.

Disabled

P16

Personnel No.

Disabled

Table 2 Statistics

P10:Machine Speed
Select this parameter to view the current machine speed expressed in meters per minute (m/min)

P11: Production Time
Select this parameter to view the length of time for which the machine drive is activated - shown in hours (deci-