PAGE 33 TP10476-1

4.8 Waste Count
The Waste Count is the difference between the Total Input
Count and the Total Output Count.
Waste Count is accessible by pressing and holding the Total
Count button followed by pressing the Total Output Count
button.
Waste Count can range from 0 to 99,999,999.
This process variable is not stored in memory.
Reset job will clear this process variable to zero.

5. Counter Setup Variables

5.1 Batch Preset
This parameter is accessible only in Counter Setup mode for
the DCT500.
This parameter specifies the batch count that will be used by
the Batch Count Down. Zero is the default setting.
This value can range from 0 to 999.

5.2 Batch Output Type
This parameter is accessible only in Counter Setup mode for
the DCT500.
This parameter specifies the batch output type that will be
used when the Batch Count Down reaches zero.
Available choices are Feed (FED), Delivery (DEL), Speed
(SPD), and Table (TBL).

5.3 Batch Output Time
This parameter is accessible only in Counter Setup mode for
the DCT500.
This parameter specifies the output duration or delay that will
be used when the Batch Count Down reaches zero.
Available ranges are determined by the Batch Output Type
selected. The Table below shows the ranges for each output
type.

5.4 Sheet Length
This parameter is accessible in the Learn mode for the
DCT500.
This parameter specifies the length of the paper that will be
fed into the machine.
Available range is 6.0 inches to 59.0 inches. 6.0 inches is
the default selection.

5.5 Gap Length
For the DCT500, this parameter is accessible in Run mode and
Learn mode.
This parameter specifies the length of gap to use between
sheets of paper that are fed into the machine.
Available range is 0.2 inches to 98.0 inches. 2.0 inches is
the default selection.

5.6 Suction Length
For the DCT500, this parameter is accessible in Run mode and
Learn mode.
This parameter specifies the suction length used on a sheet
of paper that is fed into the machine.
Available range is 5% to 50% in 5% increments. 30% is the
default.

Output

Delay

Duration

Type

Min. Time

Max. Time

Min. Time

Max. Time

Feed

Not applicable

0.0 Sec.

9.9 Sec.

Table

0.000 Sec.

1.000 Sec.

100 ms

Delivery

0.000 Sec.

1.000 Sec.

25 ms

Speed

Not applicable

0.00 Sec.

5.55 Sec.

Table 17. Output Delay and Duration