Baumfolder BAUM 26_30: Folder 1st Station Contfeed User Manual

Page 34

Advertising
background image

TP10476-1

PAGE 34

6. System Messages and Run Messages

6.1 Power-Up Fault Messages
Messages that are displayed during power on self-test.
If PLC System Errors are shown in the display, call service.

English

German

Codes

TYPE

DESCRIPTION

88888

88888

88888

Information

The controller is performing its lamp test.

MEM

MEM

MEM

Information

The controller is performing its RAM test.

TEST

TEST

TEST

all blank

all blank

all blank

PLC System

The display board is not functioning.

Error

Action: Cycle power. If error persists, call service.

ID Fail

ID Fail

ID Fail

PLC System

System cannot recognize the controller board.

Error

Action: Cycle Power, if error persists, call service.

Error 1

Error 1

Error 1

PLC System

The RAM test has found a bad memory location.

Error

Action: Cycle Power, if error persists, call service.

Error 2

Error 2

Error 2

PLC System

The Pile Safety Relay is stuck on or there is no power supply

Error

to the pile circuits.
Action: Check the condition of Relay 1 K1, Fuses F1 and F2, and
X18. Cycle Power, if error persists, call service.

Error 3

Error 3

Error 3

PLC System

There is power in the Pile Drive when it is off.

Error

Action: Check the condition of Relay 1 K1, Fuses F1 and F2, and
X18. Cycle Power, if error persists, call service.

Error 4

Error 4

Error 4

PLC System

The 24VAC inputs have current before the Watchdog

Error

relay has been activated.
Action: Check for stuck push buttons, faulty sensors, or loose
connectors.Cycle Power, if error persists, call service.

Error 5

Error 5

Error 5

PLC System

The membrane switch panel has a key pressed

Error

during the power on self-test.
Action: Cycle Power, if error persists, call service.

Error 6

Error 6

Error 6

PLC System

The Watchdog sense circuit indicates Watchdog timer operational

Error

before it has been started.
Action: Cycle Power, if error persists, call service.

Error 6.1

Error 6.1

Error 6.1

PLC System

Incorrect software in Eprom. Check Eprom type and files.

Error

Table 18. Power Up Fault Messages