Baumfolder BAUM 26_30: Folder 1st Station Contfeed User Manual

Page 24

Advertising
background image

TP10476-1

PAGE 24

P30: Port 1 Inputs
P30 indicates Port 1 input status.

P31: Port 2 Inputs
P31 indicates Port 2 input staus

P32: Port 3 Inputs
P32 indicates Port 3 input status

P33: Port 4 Inputs
P33 indicates Port 4 input status

P34:Port 5 Inputs
P34 indicates Port 5 input status

P35: Port 1 Outputs
P35 indicates Port 1 output status

Table 5 Safety settings

#

Function

Operation

Key Combin.

Variable Displayed

P60

Drive start key delay

Adjustable with

0 - 13 secs.

P61

K2 release time

Adjustable mit RP2 Adjuster-

K2 Delayed release (sec)

(large display)

+

P60: Drive Start Delay period (only when A02=0)
Entering the Drive Start Delay period for Station 1 (Settings: 0 to 13.0 sec.) ensures that the paper runs
smoothly after starting if there is any paper still inside the machine. (Station 1: approx. 0.6 sec.)

P61: Display of delayed release for the K2 guard (only when A02=0)
Adjuster for setting the K2 delayed release (Measuring time = 0 to 10 sec.). Adjust with the RP2 poti on the
SGM-3 board. Default setting = approx. 2.5 sec.

#

Function

Type

Variable Displayed

P40

Mon. time for Knife 1

Variable function

Input X26/1, P32.5

Time in milliseconds

P41

Mon. time for Knife 2

Variable function

Input X26/2, P32.4

Time in milliseconds

P42

Folding station delivery

Variable function

Input X30/5, P34.3

Time in milliseconds

P43

Counting input

Variable function

Input X25/5, P32.7

Time in milliseconds

P44

Knife 1 strokes

Variable function

Input X26/2, P32.4

Time in milliseconds

P45

Knife 2 strokes

Variable function

Input X26/5, P32.2

Time in milliseconds

P40: Time: Knife 1
Knife 1: Light sensor cover time in milliseconds.

P41: Time: Knife 2
Knife 2: Light sensor cover time in milliseconds.

Table 6 Machine statistics

Advertising