3. Controller Input Description

3.1 Table Inputs

Input

Type

Connector Point

Indicator

Name

DCI-1

NPN 24VDC

X14/2

P31.1

Pile Sensor

DCI-2

NPN 24VDC

X14/5

P14.8

Photoeye Suction Wheel

DCI-3

PNP 24VDC

X25/5

P32.7

Delivery Count Input

DCI-4

NPN 24VDC

X15/2

LED 1

Encoder

DCI-5

NPN 24VDC

X26/1

P32.5

Sheet Control Knife 1

DCI-6

NPN 24VDC

X26/2

P32.4

Sheet Control Knife 2

DCI-7

NPN 24VDC

X26/4

P32.3

Knife Manual

DCI-9

PNP 24VDC

X26/8

P32.1

Ergonomic Pile Make Ready

DCI-10

24VDC

X30/5

P34.3

Light sensor - Folding station del.

DCI-11

24VDC

X30/11

P34.2

Folding station - Make Ready

ACI-1

24VAC

X21/1, X21/2, X23/3

P30.8

Drive is on

ACI-2

24VAC

X11/3, X22/2, X23/4

P31.8

Emergency Stop/Drive Stop

ACI-3

24VAC

X22/3

P31.7

Jammed Sheet

ACI-4

24VAC

X22/4

P31.6

Drive Thermal Fault

ACI-5

24VAC

X21/5, X23/9

P31.5

Sheet Stop Button

ACI-6

24VAC

X21/6, X23/11

P31.4

Sheet Start Button

ACI-7

24VAC

X11/2

P31.3

Pile is down

ACI-8

24VAC

X11/6

P31.2

Double Sheet Fault

ACI-9

24VAC

X23/5

P30.7

Compressor Start Button

ACI-10

24VAC

X23/6

P30.6

Compressor Stop Button

ACI-11

24VAC

X23/10

P30.4

Pile Stop Button

ACI-12

24VAC

X23/12

P30.3

Pile Down (backward) Button

ACI-13

24VAC

X23/14

P30.5

Pile Up (forward) Button

ACI-14

220VAC

Internal

P30.2

Function Control K1

ACI-15

220VAC

Internal

P30.1

Function Control Pile

ACI-16

24VAC

X29/5

P34.5

K2 protective relay monitor

ACI-17

24VAC

X29/7

P34.4

External device monitor

ACI-18

24VAC

X29/1

P34.8

Emergency stop - control panel

ACI-19

24VAC

X29/2

P34.7

Emergency stop - guard

ACI-20

24VAC

X29/3

P34.6

Emergency stop - next stations

ACI-24

24VAC

X19/2

P34.1

External mis-fed sheet

Table 15. Inputs

3.2 24VAC Inputs

Several mechanical switches are used to indicate machine
faults. These faults are described here. If these faults occur
when the machine is not running, they will display the
associated fault message until the fault is cleared. The only
exception is the Safety fault. The Safety fault always
requires removal of power before the machine can be used
again. If a fault occurs while the machine is running, the
method used to clear the fault varies from fault to fault.

Double Sheet
The Double Sheet switch is used to sense multiple sheets
being fed into the machine at the same time. If this fault occurs,
the message “2 Sheet” will be displayed and sheet feeding will
stop. The Drive and Compressor outputs will continue
unaffected. Once the fault has been cleared the machine can
start feeding sheets again by pressing the Sheet Start switch.

Advertising